Guides / Facade Systems
A kinetic facade is a building skin whose surface is made of moving panels rather than a fixed sheet. Wind-driven systems turn under the air alone, with no power or controls; motorised systems use actuators and a controller to move the panels on command. This guide sets out the difference, how a wind-driven system works, and the fields to put on the specification so the supplier quotes the facade you drew.
A kinetic facade is an envelope whose surface moves. The panels — flaps, fins or louvers — turn on their fixings, so the wall reads as a changing surface instead of a static one. The split that matters for a buyer is how the movement is driven: by the wind alone, or by motors.
On a wind-driven facade each flap is a light aluminium panel carried on a horizontal axle, and moving air turns it. Because the flaps across the elevation meet the same gust at slightly different moments, the movement travels across the wall as a wave. On a motorised facade, actuators and a controller drive the panels to a programme. The first is passive and runs at no power cost; the second gives you precise, repeatable movement but adds a powered system to design, run and maintain.
A conventional facade is a fixed sheet or screen. A kinetic facade is the same idea with motion added: the panels are mounted so they can turn, flap or swing, and the movement is either triggered by the environment or commanded by a control system. The elevation changes through the day — with the light, the wind and the viewing angle — which is why architects use it on blank walls that would otherwise read as dead surface.
Two families cover almost every enquiry. A wind-driven facade is passive: the wind is the actuator, and there are no motors, sensors or control cabinets to power, program or service. A motorised facade uses actuators and a controller, so the movement is exact but the system carries power, wiring and the servicing that goes with them. The kinetic facade page covers the wind-driven system in detail.
It is easy to confuse a kinetic facade with a fixed decorative screen. A fin or louvre facade is static — its blades are set at an angle and stay there. A kinetic facade is the moving version: the panels themselves turn. The fin facade guide keeps the static family separate.
The two systems look similar on a render and behave differently on site. The choice comes down to whether you need controlled motion or simply motion.
| What you compare | Wind-driven | Motorised |
|---|---|---|
| Power | None — wind is the actuator | Actuators and a controller |
| Movement | Emergent, wave-like, not scripted | Programmed, repeatable patterns |
| Running cost | None | Power plus control servicing |
| Maintenance | Periodic inspection of axles and fixings, coating cleaning | Motors, sensors and wiring to service |
| Typical use | Facades that want movement with no running cost | Facades that need precise, scheduled motion |
The practical rule: pick wind-driven where the brief says “the wall should move” and motorised where the brief says “the wall should do this at this time”. The second is a powered installation with everything that implies.
The mechanism is mechanical, not electronic. Each flap is a light aluminium panel carried on a horizontal axle, and the wind turns it. Flaps, axles, carrier brackets and the sub-frame are engineered as one package and fixed back to the structural opening, so the whole elevation is a single assembly rather than a set of loose screens.
The wave effect comes from the fact that the flaps do not all meet a gust at once. A gust passes across an elevation over a fraction of a second, so each flap turns a moment after its neighbour. The result reads as ripples travelling over the wall — the same reason a field of grass moves in patches rather than as one block.
Because there is no control system, the engineering moves into the mechanics: axle spacing and restraint are set against the wind loading requirement of the structural engineer. The goal is a flap that turns freely in normal air and stays within its designed range in a storm. That is where the wind-load standard enters the design, covered below.
The facade is made to order, so the specification is a list of fields rather than a catalogue pick. The values below are the production specification on the kinetic facade page.
| What you specify | Range / options | Why it matters |
|---|---|---|
| Aluminium thickness | 0.6 – 3.0 mm | Sets the weight of each flap, so how readily it turns |
| Flap size | Made to order | Sets the scale of the wave on the elevation |
| Edge profile | Straight edge / bevel edge | Changes how the panel catches the light |
| Finish | PVDF / powder coat / anodized (incl. copper & bronze) / wood-grain / stone-grain / mill finish | Weathering and appearance |
| Fixing | Carrier frame and axle system | Transfers wind load back to the structure |
| Engineering | Axle spacing and restraint vs wind load | Keeps the flap within its designed range |
Nothing on the system is a catalogue dimension. It is engineered against the elevation and the local wind load, so the drawing is the real specification and the table fields pin the variables down on top of it.
The system earns its keep on elevations that would otherwise be a blank panel wall. Car park and podium screens, retail and mall facades where the client wants movement without a running cost, and cultural or civic buildings where the wall reads as a changing surface are the standard list. Plant-room and service screens use it where airflow still has to pass through, and office or hotel elevations suit it on sites with steady prevailing wind.
It is not the answer where movement has to be scripted, or where the site has no reliable wind to animate it. A facade on a sheltered, low-wind elevation will move rarely and read as a static screen most of the time — at which point a fixed fin or a motorised system is the better call. The cladding guide sets out the fixed-panel alternative.
Three standards frame the design. The wind load the structure must take is defined by EN 1991-1-4, the Eurocode for wind actions on structures; the facade's axle spacing and restraint are set against that figure. The aluminium itself is designed to EN 1999-1-1, the Eurocode for aluminium structures — aluminium is about 2700 kg/m³, which is why a thin flap stays light enough to turn in a breeze. The build-up is classified for reaction to fire under EN 13501-1.
The practical limit is the wind, not the panel. A flap that turns freely in normal air must also survive a storm gust without being torn off its axle or banging against its neighbour. That is why the supplier asks for the wind loading requirement from your structural engineer before quoting, and why a kinetic elevation cannot be priced off a plan alone.
Put the fields below on one sheet and send it with the drawing, so each supplier quotes the same facade:
Weight follows from the same fields: a thin aluminium flap weighs less than a thick one and turns more readily, which is why the 0.6 to 3.0 mm band matters to behaviour, not just to cost. Finish is a separate decision, covered with the fixed systems on the cladding price page.
A building envelope whose surface is made of moving panels rather than a fixed sheet. The panels turn, flap or swing in response to wind or a control signal, so the elevation changes through the day instead of reading as a static wall.
No. The panels move on their axles under the wind alone. There is no motor, sensor or control cabinet, which is the main reason specifiers choose it over a powered kinetic facade.
A wind-driven facade is passive: the wind turns each panel and there is no power or control system. A motorised facade uses actuators and a controller to move the panels, so the movement is precise but it needs power and maintenance.
In most cases yes, subject to a review of the structure and the wind load at the opening. The supplier needs the elevation and the structural details to confirm.
Standards are cited for the definitions and methods they contain. The wind load for a project comes from the structural engineer, agreed with the supplier, not from this page.